Establishment details
Type of parking
- Interior
Reserved seat size
- Free width of at least 2.4 m
- Free width of the side aisle on the side of at least 1.5 m
Reserved seat identification
- Using the panel and on the ground
parking meter
- Slots (coin, card or parking ticket) and raised control buttons : 1,29 m
Pathway leading to the entrance
- Circulation corridor at least 1.1 m wide
- Accessible driveway leading to the entrance
Elevator
- Maneuvering space at least 1.5 m wide x 1.5 m deep located in front of the door
- Dimension of at least 0.80 m wide x 1.5 m deep
- Free width of the door opening at least 80 cm
Driveway leading to the entrance
- Free width of at least 1.1 m
Interior entrance door
- Maneuvering space of at least 1.5 m x 1.5 m
- Difference in level between the interior floor covering and the door sill : 2 cm
- Insufficient clear width : 74 cm
- Opening requiring significant physical effort
- No electric opening mechanism
Indoor circulation
- Maneuvering space of at least 1.5 m in diameter
- Circulation corridor of at least 92 cm
Bed(s)
- Mattress Top : 62 cm above floor
- Clearance under the bed of at least 15 cm
Work desk
- Desk surface located between 68.5 cm and 86.5 cm above the floor
- Clearance under the desk of at least 68.5 cm above the floor
Bed(s)
- King-size bed
- Transfer zone on side of bed exceeds 92 cm
Front door
- Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
- Difference in level between the interior floor covering and the door sill : 2 cm
- Clear Width : 74 cm
Interior maneuvering area
- Maneuvering area : 0,67 m width x 1,33 m depth
Toilet bowl
- Center (axis) located at : 64 cm from the nearest adjacent wall
- No transfer zone on the side of the bowl
- Toilet bowl seat located at a height of : 39 cm above the ground
Grab bar to the right of the toilet
- No grab bar
Grab bar to the left of the toilet
- No grab bar
Grab bar behind the toilet
- No grab bar
Sink
- Maneuvering area in front of the sink : 67 cm width x 120 cm depth
- Surface located at a height between 68.5 cm and 86.5 cm above the ground
- Height of clearance under sink : 59 cm
- Faucets located at a distance of : 57 cm from the edge of the sink
Bath
- Height rim of : 32 cm from the ground
Bath: grab bar on left side wall
- No grab bar
Bath: grab bar on right side wall
- No grab bar
Bath: grab bar on the wall facing the entrance
- Horizontal or L-shaped bar
- Length : 65 m
- Situated at : 47 cm above the edge of the bath
Bath
- Round faucets
- No telephone showerhead
Driveway leading to the entrance
- Free width of at least 1.1 m
Interior entrance door
- Maneuvering space of at least 1.5 m x 1.5 m
- Insufficient clear width : 74 cm
- Opening requiring significant physical effort
- No electric opening mechanism
Indoor circulation
- Maneuvering space of at least 1.5 m in diameter
- Circulation corridor of at least 92 cm
Bed(s)
- Mattress Top : 66 cm above floor
- Clearance under the bed of at least 15 cm
Work desk
- Desk surface located between 68.5 cm and 86.5 cm above the floor
- Clearance under the desk of at least 68.5 cm above the floor
Bed(s)
- King-size bed
- Transfer zone on side of bed exceeds 92 cm
Front door
- Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
- Difference in level between the interior floor covering and the door sill : 2 cm
- Clear Width : 74 cm
Interior maneuvering area
- Maneuvering area : 1,35 m width x 0,82 m depth
Toilet bowl
- Center (axis) located at : 70 cm from the nearest adjacent wall
- No transfer zone on the side of the bowl
- Toilet bowl seat located at a height between 43 cm and 48.5 cm above the floor
Grab bar to the right of the toilet
- No grab bar
Grab bar to the left of the toilet
- No grab bar
Grab bar behind the toilet
- No grab bar
Sink
- Maneuvering area in front of the sink at least 80 cm wide x 1.2 m deep
- Surface located at a height between 68.5 cm and 86.5 cm above the ground
- Height of clearance under sink : 66 cm
- Faucets located at a distance of : 45 cm from the edge of the sink
Bath
- Height rim of : 36 cm from the ground
Bath: grab bar on left side wall
- Horizontal, oblique or L-shaped bar
- Length : 65 cm
- Lower end located at : 49 cm above the edge of the bath
Bath: grab bar on right side wall
- No grab bar
Bath: grab bar on the wall facing the entrance
- Horizontal or L-shaped bar
- Length : 0,65 m
- Situated at : 49 cm above the edge of the bath
Washbasin
- Surface between 68.5 cm and 86.5 cm above the floor
- Clearance under sink : 59 cm above floor
Accessible washroom(s)
- Dimension of at least 1.5 m wide x 1.5 m deep
Accessible toilet cubicle door
- Clear door width : 74 cm
Accessible washroom bowl
- Transfer zone on the side of the toilet bowl of at least 87.5 cm
Accessible washroom(s)
- 1 toilet cabin(s) adapted for the disabled / 2 cabin(s)
- Near swimming pool: manoeuvring space with diameter of at least 1.5 m available
- Swimming pool: no equipment adapted for disabled persons
- Access to swimming pool
Aisle leading to the locker room entrance
- Circulation corridor at least 1.1 m wide
Entrance door to the locker room
- Opening requiring significant physical effort
- No electric opening mechanism
Description
Height of the bed (room 1115) : 62cm
Height of the bed (room 1425) : 66cm
Contact details
360, rue Saint-Antoine Ouest, Montréal, Québec
514 987 9900, 800 361 3600, montreal@ihg.com
Visit the website