Hôtel Comfort Inn Laval
Back to the results pageAccessibility features
Evaluation year by Kéroul: 2024
Hôtel Comfort Inn Laval
2055, aut. des Laurentides
Laval, (Québec)
H7S 1Z6
Phone 1: 450 686 0600
Phone 2:
1 800 465 6116
Website
:
www.lavalcomfortinn.com
Email: cn331r@whg.com
Number of accessible rooms : 0
Number of rooms : 119
Accessibility
Parking |
(situé : Sur le côté du bâtiment )
Type of parking
Outside
Presence of slope
Gentle slope
Number of reserved places
Reserved seat(s) for people with disabilities: : 2
Route leading from the parking lot to the entrance
Accident : Asphalte brisée à plusieurs endroits
Exterior Entrance |
(Main entrance)
Pathway leading to the entrance
On a gentle slope
Circulation corridor at least 1.1 m wide
Step(s) leading to entrance
Ground level
Front door
Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
Difference in level between the exterior floor covering and the door sill : 5,2 cm
No electric opening mechanism
Exterior Entrance |
(Secondary entrance)
2nd Entrance Door
Interior round or thumb-latch handle
Interior of the building
Number of accessible floor(s) / Total number of floor(s)
1 accessible floor(s) / 2 floor(s)
Staircase
Handrails on each side
Counter
Reception desk
Counter surface : 1,27 cm above floor
No clearance under the counter
Wireless or removable payment terminal
Movement between floors
No machinery to go up
Universal washroom |
(located : Près de la salle de buffet)
Signage on the door
Signage on the entrance door
Door
Interior maneuvering space : 1,9 m wide x 1,3 m deep in front of the door
Lateral clearance on the side of the handle : 28 cm
Interior maneuvering space
Restricted Maneuvering Space : 2,09 m wide x 1,14 meters deep
Toilet bowl
Center (axis) away from nearest adjacent wall : 44
Transfer zone on the side of the bowl : 67 cm
Grab bar(s)
Oblique left
Too small : 50 cm in length
Tilted the wrong way
Washbasin
Accessible sink
Restoration
: Coin petit déjeuner buffet
Internal trips
Circulation corridor of at least 92 cm
Maneuvering area of at least 1.5 m in diameter available
Payment
Removable Terminal
buffet counter
Circulation corridor leading to the counter of at least 92 cm
Maneuvering space located in front of the counter of at least 1.5 m in diameter
Counter surface : 90 cm above floor
No clearance under the counter
Tables
75% of the tables are accessible.
Room* |
( Other/ Salle diamant)
ronde
Accommodation Unit* Chambre #144
Interior entrance door
Maneuvering space of at least 1.5 m x 1.5 m
Insufficient clear width : 73 cm
Insufficient lateral clearance on the side of the handle : 9 cm
Indoor circulation
Maneuvering space of at least 1.5 m in diameter
Traffic corridor : 81 cm
Bed(s)
Mattress Top : 67 cm above floor
Clearance under the bed of at least 15 cm
Wardrobe / Coat hook
Maneuvering space ahead : 0,88 m in diameter
Door or opening : 55 cm
Rod : 1,6 m above the floor
Possibility of moving the furniture at the request of the customer
Furniture can be moved as needed
Bed(s)
1 bed
Queen-size bed
Transfer zone on side of bed exceeds 92 cm
Pathway leading to the entrance
Circulation corridor at least 1.1 m wide
Front door
Maneuvering area outside in front of the door : 2,79 m width x 0,84 m depth
Maneuvering area inside in front of the door : 1,5 m de largeur x 1,04 m depth
When you have to push the door: lateral release on the side of the handle : 15 cm
Interior maneuvering area
Maneuvering area : 1,5 m width x 1,04 m depth
Toilet bowl
No transfer zone on the side of the bowl
Toilet bowl seat located at a height of : 39 cm above the ground
Grab bar to the right of the toilet
Oblique support bar
Horizontal component located at : 101 cm above the ground
Sink
Maneuvering area in front of the sink at least 80 cm wide x 1.2 m deep
Surface located at a height of : 88 cm above the ground
Bath
Shower bath
Bath bench available on request
Bath: grab bar on left side wall
Vertical bar
Lower end located at : 40 cm above the edge of the bath
Bath: grab bar on the wall facing the entrance
No grab bar